T wall units are an ideal product where the speed of installation is necessary. They offer a fast, cost-effective solution to constructing retaining and containing developments. Standard sizes range from 2m high up to 4m high, with a width of 1m for all unit sizes.

Product Benefits

  • Large range of sizes available
  • Quick and easy installation
  • Create storage bays without imposing a load to the building frame
  • Can retain material on both sides
  • Retain material up to 18kN/m³

Foundations

The foundation requirements should be determined by a qualified engineer. Units placed on a concrete foundation should be bedded on mortar and wedged to attain correct alignment. Where it is necessary to anchor the unit to the foundation see the ‘Stability’ section below.

FP-McCann-Precast-Concrete-Walling-TWalls

Stability

Anchors compromise of 4no. B. 16 high yield deformed bars with nominal penetration of 150mm both into the foundation and the unit, used with two-part resin mortar (as for retaining walls) in accordance with the manufacturer’s instructions.

  1. Position the T-Walls onto the concrete foundation and align using a cement mortar bed and shims as required.
  2. With the 30mm diameter holes in the unit base as a guide, drill into the foundation to the required depth using a 28mm diameter rotary percussive drill to give rough sided holes (do not use a diamond drill which leaves a smooth-sided hole).
  3. Pour sufficient mixed resin into the hole first then insert the B. 16 bar to the full depth so that the resin covers and encapsulates the bar.