BEAM AND BLOCK FLOORING
When specifying beam and block flooring, many of the risks sit at the specification stage, rather than on-site. Get the beam depth or centres wrong against the loading schedule and the layout has to be redesigned once the substructure is set out. Loose detailing at the floor-to-wall junction lets linear thermal bridging give back the thermal gain the insulation was specified to deliver.
FP McCann has manufactured precast concrete since 1979 and supplies beam and block flooring from ISO-accredited plants across the UK and Ireland. We support specifiers at the point these decisions are made, with beam profile and span data, U-value figures for our block and polystyrene panel systems, and quotations that state the number and type of blocks needed to complete the floor.
Architects, main contractors and groundworks subcontractors work from the same information, whether the project is a single extension or a large housing site.
Here, we discuss what you need to know to specify a beam and block (T beam) flooring system with confidence.
GET IN TOUCH
TECHNICAL DOWNLOADS
WHAT IS A BEAM AND BLOCK FLOOR?
A beam and block floor is built from precast, prestressed concrete beams laid across or between load-bearing walls, then infilled with concrete blocks or polystyrene panels.
It is a dry construction method. There is no formwork, no propping and no curing period, so the floor becomes a working platform for following trades as soon as the infill is grouted.
The system suits suspended ground floors and upper floors in residential and other building types. On ground floors it has largely displaced the in-situ slab, particularly where ground conditions rule out a ground-bearing slab.
NHBC Standards Chapter 5.2 requires a suspended ground floor where the depth of fill exceeds 600mm, where soil swelling may occur, on sites subject to vibratory ground improvement, or where the ground cannot support a ground-bearing slab. Those conditions cover a large share of UK housing plots.


BEAM PROFILES AND SPANS
FP McCann manufactures prestressed concrete floor beams in two depths – 150mm and 225mm deep.
Beam centres are set by the width of the infill block and by the load the floor carries. A layout is designed against the loading schedule for the plot rather than picked off a standard arrangement.
Choosing beam depth and centres
Four things drive the decision: clear span, imposed load, the position of any load-bearing partitions, and point loads from items such as columns or stair strings.
Where the span exceeds what a single beam run can carry, a sleeper wall or intermediate support brings it back within range. Resolve this early. A sleeper wall added late affects the substructure and the drainage layout beneath the floor.
Full beam profile and load span data is available on our beam and block (T beam) flooring system page.
INFILL OPTIONS AND THERMAL PERFORMANCE
Two infill routes are available – concrete blocks, or polystyrene panels where the floor is carrying the thermal line.
Block infill remains the straightforward choice where insulation sits above the structural floor. Our quotations stipulate the number and type of blocks required to complete the floor, which removes a common source of ordering error.
Where the floor itself has to deliver the U-value, we offer two polystyrene panel systems.


COMPLIANCE AND STANDARDS
Beam and block systems are covered by BS EN 15037. Part 1 covers the beams, Part 2 concrete infill blocks and Part 4 expanded polystyrene blocks.
Other requirements that shape the design:
- Part C. The floor must resist moisture and ground gas reaching the building. NHBC Chapter 5.2 calls for a clear void of not less than 150mm below the underside of the beams, ventilated by openings of not less than 1,500mm² per metre run of external wall or 500mm² per m² of floor area, on at least two opposite sides.
- Part E. Where the floor separates dwellings, the mass of the floor and the detailing at its perimeter carry the acoustic performance.
- Part B. Fire resistance of the floor construction.
- Factory production control and UKCA marking under the harmonised standard.
We run CPD seminars on precast flooring for practices that want to work through this in detail.
INSTALLATION ON SITE
Beams are delivered against a layout drawing and placed either by crane or by hand, depending on depth, length and site access. Infill blocks are laid dry between the beams and the joints brushed with a sand-cement grout.
Once grouted, the floor is a safe working platform. Unlike an in-situ slab, it is not held up by frost, rain or a curing period, which is why it sits well on a tight housing programme.
The programme risk on a beam and block floor is rarely the product. It is access, crane position and delivery sequencing. Those are worth working through at pre-start.
Beams are available on a supply only or a supply and fix basis.

WHEN BEAM AND BLOCK IS NOT THE RIGHT ANSWER
Beam and block does not suit every floor.
- Long spans and heavy point loads may be better served by hollowcore flooring.
- Irregular plan geometry with many openings generates a lot of trimming and cutting, which erodes the speed advantage.
- Sites with no crane position and no hand-placing route will struggle with 225mm beams over longer spans.
- Where a deep void or an extensive dwarf wall arrangement is needed, the substructure cost can outweigh the saving over an in-situ solution.
Raising these at design stage costs nothing. Raising them on site costs programme.
SPECIFYING AND ORDERING FROM FP MCCANN
At FP McCann, we have built strong, lasting relationships with contractors, architects, and civils teams across the UK construction sector. Our customers trust us because we deliver what we promise – high-quality precast concrete products, reliable service, and practical support at every stage of the project.
We operate from 14 state-of-the-art manufacturing facilities strategically placed throughout the United Kingdom and Northern Ireland which enables us to service the construction sector with precast concrete efficiently. Indeed, we have a new £30m state-of-the art concrete roof tile manufacturing facility built in Cadeby, Leicestershire which uses solar panels to provide 100% of the plant’s energy requirement.
We supply projects of every scale, from single extensions to large housing sites.
To discuss a beam and block flooring requirement or find your local stockist, contact our team on 01335 361269, request a quote or download our flooring brochure.